{"id":6510,"date":"2026-04-21T17:55:07","date_gmt":"2026-04-21T17:55:07","guid":{"rendered":"https:\/\/vicentevilasl.com\/staging\/?page_id=6510"},"modified":"2026-07-30T06:51:44","modified_gmt":"2026-07-30T06:51:44","slug":"sistema-corredera-v120-rpt","status":"publish","type":"page","link":"https:\/\/vicentevilasl.com\/de\/productos\/sistema-corredera-v120-rpt\/","title":{"rendered":"V120 RPT Schiebesystem"},"content":{"rendered":"<div class=\"contenido\">\n<div class=\"container-fluid swf title-product-max\">\n<section class=\"section-22\"  style=\"flex:1;\">\n<h2 class=\"elementor-heading-title elementor-size-default title_product\">V120 RPT<\/h2>\n<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"\/de\/productos\/\" class=\"title_family\">\u2190 Produkte<\/a><\/h2>\n<\/section>\n<section  class=\"section-22 section-22b\"><a class=\"btn-ficha\"  href=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/07\/ficha-tecnica-V120-RPT.pdf\" target=\"_blank\">PDF-Datenblatt<\/a><\/section>\n<\/div>\n<div class=\"container-fluid\">\n<div class=\"body\">\n<div id=\"wf-node-002\" class=\"w-layout-layout quick-stack-54 wf-layout-layout\">\n<div class=\"w-layout-cell cell-126\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/Escuadra-V120-RPT-V3-RET.jpg\" alt=\"\"><\/div>\n<div class=\"w-layout-cell cell-140\">\n<p class=\"paragraph-50\">Schiebet\u00fcr mit thermischer Trennung, 120 mm breit, f\u00fcr h\u00f6here Energieeinsparungen, W\u00e4rme- und Schalld\u00e4mmung sowie zur Verhinderung der Temperatur\u00fcbertragung von au\u00dfen nach innen.<\/p>\n<div id=\"wf-node-003\" class=\"w-layout-layout quick-stack-49 wf-layout-layout\">\n<div class=\"w-layout-cell cell-118\">\n<h2 class=\"elementor-heading-title elementor-size-default title_caract\">EIGENSCHAFTEN<\/h2>\n<\/div>\n<\/div>\n<div id=\"wf-node-015\" class=\"w-layout-layout quick-stack-48 wf-layout-layout\">\n<div class=\"w-layout-cell cell-102\">\n<p class=\"paragraph-43\">\u00dcbertragung<\/p>\n<\/div>\n<div class=\"w-layout-cell cell-101\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2025\/12\/thermometer.png\" alt=\"\" class=\"image-45\"><\/div>\n<div class=\"w-layout-cell cell-103\">\n<p class=\"paragraph-46\">Uw: 1,6 (W\/m\u00b2K)<\/p>\n<\/div>\n<\/div>\n<div id=\"wf-node-004\" class=\"w-layout-layout quick-stack-48 wf-layout-layout\">\n<div class=\"w-layout-cell cell-102\">\n<p class=\"paragraph-43\">Schalld\u00e4mmung<\/p>\n<\/div>\n<div class=\"w-layout-cell cell-101\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2025\/12\/volume.png\" alt=\"\" class=\"image-46\"><\/div>\n<div class=\"w-layout-cell cell-103\">\n<p class=\"paragraph-46\">42 (-1,-2)dB<\/p>\n<\/div>\n<\/div>\n<div id=\"wf-node-005\" class=\"w-layout-layout quick-stack-48 wf-layout-layout\">\n<div class=\"w-layout-cell cell-102\">\n<p class=\"paragraph-43\">Luftdurchl\u00e4ssigkeit<\/p>\n<\/div>\n<div class=\"w-layout-cell cell-101\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2025\/12\/Air.png\" alt=\"\" class=\"image-47\"><\/div>\n<div class=\"w-layout-cell cell-103\">\n<p class=\"paragraph-46\">Klasse 3<\/p>\n<\/div>\n<\/div>\n<div id=\"wf-node-006\" class=\"w-layout-layout quick-stack-48 wf-layout-layout\">\n<div class=\"w-layout-cell cell-102\">\n<p class=\"paragraph-43\">Wasserdichtigkeit<\/p>\n<\/div>\n<div class=\"w-layout-cell cell-101\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2025\/12\/drop.png\" alt=\"\" class=\"image-48\"><\/div>\n<div class=\"w-layout-cell cell-103\">\n<p class=\"paragraph-46\">Klasse 4A<\/p>\n<\/div>\n<\/div>\n<div id=\"wf-node-007\" class=\"w-layout-layout quick-stack-48-copy wf-layout-layout\">\n<div class=\"w-layout-cell cell-102\">\n<p class=\"paragraph-43\">Windwiderstand<\/p>\n<\/div>\n<div class=\"w-layout-cell cell-101\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2025\/12\/wind.png\" alt=\"\" class=\"image-49\"><\/div>\n<div class=\"w-layout-cell cell-103-copy\">\n<p class=\"paragraph-46\">Klasse C3<\/p>\n<\/div>\n<\/div>\n<p class=\"paragraph-47\">Referenztest AEV 2,40 x 2,20 m \/ 2 Platten<\/p>\n<\/div>\n<\/div>\n<div id=\"wf-node-009\" class=\"w-layout-layout quick-stack-46 wf-layout-layout\">\n<div class=\"w-layout-cell\">\n<div id=\"wf-node-008\" class=\"w-layout-layout quick-stack-51 wf-layout-layout\">\n<div id=\"wf-node-010\" class=\"w-layout-cell cell-111\">\n<div id=\"wf-node-011\" class=\"w-layout-layout quick-stack-56 wf-layout-layout\">\n<div class=\"w-layout-cell\">\n<div id=\"wf-node-012\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/V120-RPT.svg\" alt=\"\" class=\"image-151\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"w-layout-cell cell-110 paragraph-43\">\n<p class=\"paragraph-43\"><strong>Abschnitte<\/strong><br \/>Rahmen 120 mm, Blatt 50 mm<\/p>\n<p><strong>Profildicke<br \/><\/strong>1,8 mm<\/p>\n<p><strong>RPT-L\u00e4nge<br \/><\/strong>15 mm<\/p>\n<p><strong>Verglasung<\/strong><br \/>Max. 40 mm, Min. 24 mm<\/p>\n<p><strong>Maximale Blechabmessungen<\/strong><br \/>Breite (L) 6000 mm, H\u00f6he (H) 30000 mm<\/p>\n<p><strong>max. Blattgewicht<\/strong><br \/>400 kg<\/p>\n<p> <img decoding=\"async\" src=\"\" alt=\"\" class=\"image-51\"> <\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"w-layout-layout quick-stack-46 wf-layout-layout\">\n<div id=\"img_product\" class=\"w-layout-cell\">\n<div id=\"view3d\">\n        <div class=\"modelViewerBlock\" data-attributes='{&quot;model&quot;:{&quot;modelUrl&quot;:&quot;https:\\\/\\\/vicentevilasl.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/V120-Modelado-3D-Viewer.glb&quot;,&quot;poster&quot;:&quot;&quot;,&quot;arEnabled&quot;:false,&quot;arMode&quot;:&quot;webxr&quot;,&quot;arPlacement&quot;:&quot;floor&quot;,&quot;modelISOSrc&quot;:&quot;&quot;},&quot;align&quot;:&quot;center&quot;,&quot;uniqueId&quot;:&quot;model7410&quot;,&quot;currentViewer&quot;:&quot;modelViewer&quot;,&quot;O3DVSettings&quot;:{&quot;isFullscreen&quot;:true,&quot;camera&quot;:null,&quot;mouseControl&quot;:true,&quot;zoom&quot;:false},&quot;lazyLoad&quot;:false,&quot;loading&quot;:&quot;auto&quot;,&quot;zoom&quot;:false,&quot;preload&quot;:&quot;auto&quot;,&quot;mouseControl&quot;:true,&quot;fullscreen&quot;:true,&quot;zoomInOutBtn&quot;:false,&quot;cameraBtn&quot;:false,&quot;loadingPercentage&quot;:false,&quot;progressBar&quot;:true,&quot;exposure&quot;:&quot;1&quot;,&quot;shadow&quot;:1,&quot;woo&quot;:false,&quot;placement&quot;:&quot;shortcode&quot;,&quot;styles&quot;:{&quot;width&quot;:&quot;100%&quot;,&quot;height&quot;:&quot;700px&quot;,&quot;bgColor&quot;:&quot;#ffffff&quot;}}'>\n            <div class=\"bp3d_backup_view\" style=\"display: none;height:350px;\">\n                <model-viewer camera-controls src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/V120-Modelado-3D-Viewer.glb\" style=\"height: 350px;\"><\/model-viewer>\n            <\/div>\n        <\/div>\n\n        <\/div>\n<div><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/V120-RET.jpg\" alt=\"\" class=\"image-68\"><\/div>\n<div id=\"wf-node-013\" class=\"w-layout-layout quick-stack-55 wf-layout-layout\">\n<div class=\"w-layout-cell cell-122\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/Img-1.1-V120.png\" alt=\"\"><\/div>\n<div class=\"w-layout-cell cell-123\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/Img-2-V120.png\" alt=\"\"><\/div>\n<div class=\"w-layout-cell cell-121\"><img decoding=\"async\" src=\"https:\/\/vicentevilasl.com\/wp-content\/uploads\/2026\/06\/Img-3.1-V120.png\" alt=\"\"><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>V120 RPT \u2190 Productos FICHA PDF Corredera con Rotura de Puente T\u00e9rmica de 120 mm de ancho, obteniendo un mayor ahorro energ\u00e9tico, aislamiento t\u00e9rmico y ac\u00fastico, evitando las transmisi\u00f3n de la temperatura del exterior al interior. CARACTER\u00cdSTICAS Transmitancia Uw: 1,6 (W\/m\u00b2K) Aislamiento ac\u00fastico 42 (-1,-2)dB Permeabilidad al aire Clase 3 Estanqueidad al agua Clase 4A Resistencia al viento Clase C3 Ensayo de referencia AEV 2,40 x 2,20 m \/ 2 hojas SeccionesMarco 120 mm, Hoja 50 mm Espesor perfiler\u00eda1,8 mm Longitud RPT15 mm AcristalamientoM\u00e1x. 40 mm, M\u00edn. 24 mm Dimensiones m\u00e1x. hojaAncho (L) 6000 mm, Alto (H) 30000 mm Peso m\u00e1x. hoja400 kg<\/p>","protected":false},"author":1,"featured_media":0,"parent":2406,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-6510","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/vicentevilasl.com\/de\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"V120 RPT \u2190 Productos FICHA PDF Corredera con Rotura de Puente T\u00e9rmica de 120 mm de ancho, obteniendo un mayor ahorro energ\u00e9tico, aislamiento t\u00e9rmico y ac\u00fastico, evitando las transmisi\u00f3n de la temperatura del exterior al interior. CARACTER\u00cdSTICAS Transmitancia Uw: 1,6 (W\/m\u00b2K) Aislamiento ac\u00fastico 42 (-1,-2)dB Permeabilidad al aire Clase 3 Estanqueidad al agua Clase 4A&hellip;","_links":{"self":[{"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/pages\/6510","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/comments?post=6510"}],"version-history":[{"count":26,"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/pages\/6510\/revisions"}],"predecessor-version":[{"id":9448,"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/pages\/6510\/revisions\/9448"}],"up":[{"embeddable":true,"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/pages\/2406"}],"wp:attachment":[{"href":"https:\/\/vicentevilasl.com\/de\/wp-json\/wp\/v2\/media?parent=6510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}